Part Number Hot Search : 
H22LTI PK130F40 CM63K LA4597 LM741 SK5822 01ZEM HMC384
Product Description
Full Text Search
 

To Download LTC4011 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Electrical Specifications Subject to Change
LTC4011 High Efficiency Standalone Nickel Battery Charger
FEATURES

DESCRIPTIO
Complete NiMH/NiCd Charger for 1 to 16 Cells No Microcontroller or Firmware Required 550kHz Synchronous PWM Current Source Controller No Audible Noise with Ceramic Capacitors PowerPathTM Control Support Programmable Charge Current: 5% Accuracy Wide Input Voltage Range: 4.5V to 34V Automatic Trickle Precharge -V Fast Charge Termination Optional T/t Fast Charge Termination Automatic NiMH Top-Off Charge Programmable Timer Automatic Recharge Multiple Status Outputs Micropower Shutdown 20-Lead Thermally Enhanced TSSOP Package
The LTC(R)4011 provides a complete, cost-effective nickel battery fast charge solution in a small package using few external components. A 550kHz PWM current source controller and all necessary charge initiation, monitoring and termination control circuitry are included. The LTC4011 automatically senses the presence of a DC adapter and battery insertion or removal. Heavily discharged batteries are precharged with a trickle current. The LTC4011 can simultaneously use both -V and T/t fast charge termination techniques and can detect various battery faults. If necessary, a top-off charge is automatically applied to NiMH batteries after fast charging is completed. The IC will also resume charging if the battery self-discharges after a full charge cycle. All LTC4011 charging operations are qualified by actual charge time and maximum average cell voltage. Charging may also be gated by minimum and maximum temperature limits. NiMH or NiCd fast charge termination parameters are pin-selectable. Integrated PowerPath control support ensures that the system remains powered at all times without allowing load transients to adversely affect charge termination.
APPLICATIO S

Integrated or Standalone Battery Charger Portable Instruments or Consumer Products Battery-Powered Diagnostics and Control Back-Up Battery Management
, LTC and LT are registered trademarks of Linear Technology Corporation. All other trademarks are the property of their respective owners. PowerPath is a trademark of Linear Technology Corporation.
TYPICAL APPLICATIO
FROM ADAPTER 4.5V TO 34V 3k INFET FAULT CHRG TOC READY VCC TGATE
2A NiMH Battery Charger
TO SYSTEM 10F LOAD
1.60 1.55
BGATE 10H
CELL VOLTAGE (V)
1.50 1.45 1.40 1.35 1.30 SINGLE CELL VOLTAGE BATTERY TEMPERATURE CHARGE CURRRENT 2A 1A TOP OFF 80 38 36 34 32 30 28 100
4011 TA01b
20k 49.9k
PGND LTC4011 DCIN SENSE TIMER BAT GND VCDIV CHEM VCELL VRT INTVDD VTEMP 0.1F 10k 10k
0.05 10F
0.033F
0.068F
30.9k 10.7k
2-CELL NiMH PACK WITH 10k NTC (2AHr)
4011 TA01a
1.25 0 20 60 40 TIME (MINUTES)
U
Typical NiMH Charge Cycle at 1C
42 40
U
U
BATTERY TEMPERATURE (C)
4011p
1
LTC4011
ABSOLUTE MAXIMUM RATINGS
(Note 1)
PACKAGE/ORDER INFORMATION
TOP VIEW DCIN FAULT CHRG CHEM GND VRT VTEMP VCELL VCDIV 1 2 3 4 5 6 7 8 9 21 20 INFET 19 READY 18 VCC 17 TGATE 16 PGND 15 BGATE 14 INTVDD 13 TOC 12 BAT 11 SENSE
VCC (Input Supply) to GND ....................... -0.3V to 40V DCIN to GND ............................................ -0.3V to 40V FAULT, CHRG, VCELL, VCDIV, BAT, TOC or READY to GND .......................... -0.3V to VCC + 0.3V SENSE to BAT ...................................................... 0.3V CHEM, VTEMP or TIMER to GND .............. -0.3V to 3.5V PGND to GND ...................................................... 0.3V Operating Ambient Temperature Range (Note 2) .................................................. - 40C to 85C Operating Junction Temperature (Note 3) ........... 125C Storage Temperature Range ................. - 65C to 150C Lead Temperature (Soldering, 10 sec).................. 300C
ORDER PART NUMBER LTC4011EFE
TIMER 10
FE PACKAGE 20-LEAD PLASTIC TSSOP
TJMAX = 125C, JA = 38C/W EXPOSED PAD (PIN 21) IS GND. MUST BE SOLDERED TO PCB TO OBTAIN SPECIFIED THERMAL RESISTANCE
Consult LTC Marketing for parts specified with wider operating temperature ranges.
ELECTRICAL CHARACTERISTICS
SYMBOL VCC Supply VCC ISHDN IQ ICC VUVLO VUV(HYST) VSHDNI VSHDND VCE INTVDD Regulator VDD IDD INTVDD(MIN) VRT IRT VFS VPC Output Voltage Short-Circuit Current (Note 6) Output Voltage Output Voltage Short-Circuit Current BAT - SENSE Full-Scale Regulation Voltage (Fast Charge) BAT - SENSE Precharge Regulation Voltage Input Voltage Range Shutdown Quiescent Current (Note 5) Quiescent Current Operating Current Undervoltage Threshold Voltage Undervoltage Hysteresis Voltage Shutdown Threshold Voltage Shutdown Threshold Voltage Charge Enable Threshold Voltage PARAMETER
The indicates specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VCC = 12V, BAT = 4.8V, GND = PGND = 0V, unless otherwise noted.
CONDITIONS
MIN 4.5
TYP
MAX 34
UNITS V A mA mA V mV mV mV mV V mA V
VCC = BAT = 4.8V Waiting to Charge (Pause) Fast Charge State, No Gate Load VCC Increasing DCIN - VCC, DCIN Increasing DCIN - VCC, DCIN Decreasing VCC - BAT, VCC Increasing No Load INTVDD = 0V VCC = 4.5V, IDD = -10mA RL = 10k VRT = 0V 0.3V < BAT < VCC - 0.3V (Note 5) BAT = 4.8V 0.3V < BAT < VCC - 0.3V (Note 5) BAT = 4.8V

5 3 5 3.95 20 -45 400 4.5 -100 3.85 3.125 3.05 -9 95 95 16 16 100 100 20 20 3.3 4.2 170 30 -25 510 5 -50
10 5 9 4.45 42 -15 600 5.5 -28
Thermistor Termination

3.475 3.55 -1 105 105 24 24
PWM Current Source

2
U
W
U
U
WW
W
V V mA mV mV mV mV
4011p
LTC4011
ELECTRICAL CHARACTERISTICS
SYMBOL VTC VLI IBAT ISENSE IOFF fTYP fMIN DCMAX VOL(TG) PARAMETER BAT - SENSE Top-Off Charge Regulation Voltage BAT - SENSE Line Regulation BAT Input Bias Current SENSE Input Bias Current Input Bias Current Typical Switching Frequency Minimum Switching Frequency Maximum Duty Cycle TGATE Output Voltage Low (VCC - TGATE, Note 7) TGATE Output Voltage High TGATE Rise Time TGATE Fall Time BGATE Output Voltage Low BGATE Output Voltage High BGATE Rise Time BGATE Fall Time Analog Channel Leakage Battery Present Threshold Voltage Battery Overvoltage Minimum Fast Charge Voltage Fast Charge Battery Fault Voltage -V Termination Automatic Recharge Voltage T Termination (Note 8) Minimum Charging Temperature (Note 8) Maximum Charge Initiation Temperature (Note 8) Maximum Fast Charge Temperature (Note 8) VTEMP Disable Threshold Voltage Pause Threshold Voltage Internal Time Base Error Programmable Timer Error
The indicates specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VCC = 12V, BAT = 4.8V, GND = PGND = 0V, unless otherwise noted.
CONDITIONS 0.3V < BAT < VCC - 0.3V (Note 5) BAT = 4.8V 5.5V < VCC < 34V, Fast Charge 0.3V < BAT < VCC - 0.1V SENSE = BAT SENSE or BAT, VCELL = 0V

MIN 6.5 6.5 -2
TYP 10 10 0.3
MAX 13.5 13.5 2
UNITS mV mV mV mA A A kHz kHz %
50 -1 460 20 98 5 VCC - 0.5 0 550 30 99 5.6 VCC 0 35 45

150 1 615
VCC > 9V, No Load VCC < 7.5V, No Load VCC - TGATE, No Load CLOAD = 3nF, 10% to 90% CLOAD = 3nF, 10% to 90% No Load No Load CLOAD = 1.6nF, 10% to 90% CLOAD = 1.6nF, 10% to 90% 0V < VCELL < 2V, 550mV < VTEMP < 2V

8.75
V V mV ns ns mV V
VOH(TG) tR(TG) tF(TG) VOL(BG) VOH(BG) tR(BG) tF(BG) ADC Inputs ILEAK Charger Thresholds VBP VBOV VMFC VFCBF VTERM VAR TTERM TMIN TMAXI TMAXC VTEMP(D) VTEMP(P) Charger Timing tTIMER tMAX
50 100 100 50
0 INTVDD - 0.075 INTVDD 35 15 100
65 65
ns ns nA

320 1.85 850 1.17 16 6 1.275 1.3 0.5 0.5 41.5 57 2.8 130 -10 -20
350 1.95 900 1.22 20 10 1.325 2 1 5 45 60
370 2.05 950 1.27 25 14 1.375 2.7 1.5 8.5 47 63 3.3 280 10 20
mV V mV V mV mV V C/min C/min C C C V mV % %
CHEM = 3.3V (NiCd) CHEM = 0V (NiMH) VCELL Decreasing CHEM = 3.3 (NiCd) CHEM = 0V (NiMH) VTEMP Increasing VTEMP Decreasing, Not Charging VTEMP Decreasing, Fast Charge

RTIMER = 49.9k
4011p
3
LTC4011
ELECTRICAL CHARACTERISTICS
SYMBOL PowerPath Control VFR VOL(INFET) VOH(INFET) tOFF(INFET) VOL ILKG IIH(VCDIV) VIL VIH IIL IIH INFET Forward Regulator Voltage Output Voltage Low Output Voltage High INFET OFF Delay Time Output Voltage Low (ILOAD = 10mA) Output Leakage Current Input Current High Input Voltage Low Input Voltage High Input Current Low Input Current High PARAMETER
The indicates specifications which apply over the full operating temperature range, otherwise specifications are at TA = 25C. VCC = 12V, BAT = 4.8V, GND = PGND = 0V, unless otherwise noted.
CONDITIONS DCIN - VCC VCC - INFET, No Load VCC - INFET, No Load CLOAD = 10nF, INFET to 50% VCDIV All Other Status Outputs All Status Outputs Inactive, VOUT = VCC VCDIV = VBAT (Shutdown) CHEM (NiMH) CHEM (NiCd) CHEM = GND CHEM = 3.3V

MIN 30 3.75
TYP 55 5.2 0 3 435 300
MAX 100 7 50 15 700 600 10 1 900
UNITS mV V mV s mV mV A A mV V A A
Status and Chemistry Select
-10 -1 2.85 -20 -20
-5 20
Note 1: Absolute Maximum Ratings are those values beyond which the life of the device may be impaired. Note 2: The LTC4011E is guaranteed to meet performance specifications from 0C to 70C. Specifications over the - 40C to 85C operating temperature range are assured by design, characterization and correlation with statistical process controls. Note 3: Operating junction temperature TJ (in C) is calculated from the ambient temperature TA and the total continuous package power dissipation PD (in watts) by the formula: TJ = TA + JA * PD Refer to the Applications Information section for details. This IC includes overtemperature protection that is intended to protect the device during momentary overload conditions. Junction temperature will exceed 125C when overtemperature protection is active. Continuous operation above the specified maximum operating junction temperature may result in device degradation or failure.
Note 4: All current into device pins is positive. All current out of device pins is negative. All voltages are referenced to GND, unless otherwise specified. Note 5: These limits are guaranteed by correlation to wafer level measurements. Note 6: Output current may be limited by internal power dissipation. Refer to the Applications Information section for details. Note 7: Either TGATE VOH may apply for 7.5V < VCC < 9V. Note 8: These limits apply specifically to the thermistor network shown in Figure 5 in the Applications Information section with the values specified for a 10k NTC ( of 3750). Limits are then guaranteed by specific VTEMP voltage measurements during test.
4011p
4
LTC4011 TYPICAL PERFOR A CE CHARACTERISTICS
PowerPath Switching
1.65 12 1.60
SINGLE CELL VOLTAGE (V)
CELL VOLTAGE (V)
VOLTAGE (V)
8 DCIN OPEN
4
0
VCC INFET DCIN 100s/DIV
4011 G09
DC674A WITH 1k SYSTEM LOAD AND 20k DCIN SHUNT, CHARGER PAUSED
NiMH Charge at 0.5C
1.60 1.55 4 SERIES NimH 2100mAHr AA CELLS CHARGED AT 0.5C SINGLE CELL VOLTAGE 1.50 1.45 1.40 CHARGE CURRENT 1.45 1.30 0 0.5A TOP OFF 15 20 40 60 80 100 120 140 160 180 200 TIME (MINUTES)
4011 G03
SINGLE CELL VOLTAGE (V)
EFFICIENCY (%)
35 30 25 20
CURRENT ERROR (%)
BATTERY TEMPERATURE 1A
Charger Soft-Start
3
10
VOLTAGE (V)
CURRENT ERROR (%)
TGATE BGATE
CURRENT ERROR (%)
5 5 0
FAST CHARGE CURRENT 1 PRECHARGE CURRENT 200s/DIV
4011 G06
UW
NiCd Charge at 1C
36 34 1.75 1.70
4 Series NiCd 1300mAhr
55 4 SERIES NiCd 1300mAhr SC CELLS CHARGED AT 2C SINGLE CELL VOLTAGE 50
BATTERY TEMPERATURE (C)
BATTERY TEMPERATURE (C)
1.55 1.50 1.45 1.40 1.35
SINGLE CELL VOLTAGE
32 30
1.65 1.60 1.55 1.50 1.45
45 40
BATTERY TEMPERATURE 1A CHARGE CURRENT
28 26 24 22 80
4011 G01
BATTERY TEMPERATURE
35 3A 2A 30 25 20 15 40
4011 G02
CHARGE CURRENT 1.40 1.35 0 10 30 TIME (MINUTES) 20 1A
1.30 0 20 40 TIME (MINUTES) 60
Charger Efficiency at DCIN = 20V, IOUT = 2A
45 40
100 95
0 -2 -4 -6 -8 -10 -12
Charge Current Accuracy
FAST CHARGE
BATTERY TEMPEATURE (C)
AMPS (A)
90 85 80 75 70 65 60 0 2 4 6 8 10 12 14 16 18 20 BATTERY VOLTAGE (V)
4011 G04
VCC = 12V BAT = 4.8V
PRECHARGE
0
10
20 30 TEMPERATURE (C)
40
50
4011 G05
Fast Charge Current Line Regulation
3 BAT = 4.8V 2 1 0 -1
Fast Charge Current Output Regulation
VCC = 20V
2 1 0 -1 0C -2 -3 50C 25C
50C 25C 0C
2
0
-2 -3 6 10 14 18 VCC (V) 22 26 30
4011 G07
0
4
8 BAT (V)
12
16
4011 G08
4011p
5
LTC4011
PI FU CTIO S
DCIN (Pin 1): DC Power Sense Input. The LTC4011 senses voltage on this pin to determine when an external DC power source is present. This input should be isolated from VCC by a blocking diode or PowerPath FET. Refer to the Applications Information section for complete details. Operating voltage range is GND to 34V. FAULT (Pin 2): Active-Low Fault Indicator Output. The LTC4011 indicates various battery and internal fault conditions by connecting this pin to GND. Refer to the Operation and Applications Information sections for further details. This output is capable of driving an LED and should be left floating if not used. FAULT is an open-drain output to GND with an operating voltage range of GND to VCC. CHRG (Pin 3): Active-Low Charge Indicator Output. The LTC4011 indicates it is providing charge to the battery by connecting this pin to GND. Refer to the Operation and Applications Information sections for further details. This output is capable of driving an LED and should be left floating if not used. CHRG is an open-drain output to GND with an operating voltage range of GND to VCC. CHEM (Pin 4): Battery Chemistry Selection Input. This pin should be wired to GND to select NiMH fast charge termination parameters. If a voltage greater than 2.85V is applied to this pin, or it is left floating, NiCd parameters are used. Refer to the Applications Information section for further details. Operating voltage range is GND to 3.3V. GND (Pin 5): Ground. This pin provides a single-point ground for internal references and other critical analog circuits. VRT (Pin 6): Thermistor Network Termination Output. The LTC4011 provides 3.3V on this pin to drive an external thermistor network connected between VRT, VTEMP and GND. Additional power should not be drawn from this pin by the host application. VTEMP (Pin 7): Battery Temperature Input. An external thermistor network may be connected to VTEMP to provide temperature-based charge qualification and additional fast charge termination control. Charging may also be paused by connecting the VTEMP pin to GND. Refer to the Operation and Applications Information sections for complete details on external thermistor networks and charge control. If this pin is not used it should be wired to VRT. Operating voltage range is GND to 3.3V. VCELL (Pin 8): Average Single-Cell Voltage Input. An external voltage divider between BAT and VCDIV is attached to this pin to monitor the average single-cell voltage of the battery pack. The LTC4011 uses this information to protect against catastrophic battery overvoltage and to control the charging state. Refer to the Applications Information section for further details on the external divider network. Operating voltage range is GND to BAT. VCDIV (Pin 9): Average Cell Voltage Resistor Divider Termination. The LTC4011 connects this pin to GND provided the charger is not in shutdown. VCDIV is an open-drain output to GND with an operating voltage range of GND to BAT. TIMER (Pin 10): Charge Timer Input. A resistor connected between TIMER and GND programs charge cycle timing limits. Refer to the Applications Information section for complete details. Operating voltage range is GND to 1V. SENSE (Pin 11): Charge Current Sense Input. An external resistor between this input and BAT is used to program charge current. Refer to the Applications Information section for complete details on programming charge current. Operating voltage ranges from (BAT - 50mV) to (BAT + 200mV). BAT (Pin 12): Battery Pack Connection. The LTC4011 uses the voltage on this pin to control current sourced from VCC to the battery during charging. Allowable operating voltage range is GND to VCC. TOC (Pin 13): Active-Low Top-Off Charge Indicator Output. The LTC4011 indicates the top-off charge state for NiMH batteries by connecting this pin to GND. Refer to the Operation and Applications Information sections for further details. This output is capable of driving an LED and should be left floating if not used. TOC is an open-drain output to GND with an operating voltage range of GND to VCC.
6
U
U
U
4011p
LTC4011
PI FU CTIO S
INTVDD (Pin 14): Internal 5V Regulator Output. This pin provides a means of bypassing the internal 5V regulator used to power the BGATE output driver. Typically, power should not be drawn from this pin by the application circuit. Refer to the Application Information section for additional details. BGATE (Pin 15): External Synchronous N-channel MOSFET Gate Control Output. This output provides gate drive to an optional external NMOS power transistor switch used for synchronous rectification to increase efficiency in the step-down DC/DC converter. Operating voltage is GND to INTVDD. BGATE should be left floating if not used. PGND (Pin 16): Power Ground. This pin provides a return for switching currents generated by internal LTC4011 circuits. Externally, PGND and GND should be wired together using a very low impedance connection. Refer to PCB Layout Considerations in the Applications Information section for additional grounding details. TGATE (Pin 17): External P-channel MOSFET Gate Control Output. This output provides gate drive to an external PMOS power transistor switch used in the DC/DC converter. Operating voltage range varies as a function of VCC. Refer to the Electrical Characteristics table for specific voltages. VCC (Pin 18): Power Input. External PowerPath control circuits normally connect either the DC input power supply or the battery to this pin. Refer to the Applications Information section for further details. Suggested applied voltage range is GND to 34V. READY (Pin 19): Active-Low Ready-to-Charge Output. The LTC4011 connects this pin to GND if proper operating voltages for charging are present. Refer to the Operation section for complete details on charge qualification. This output is capable of driving an LED and should be left floating if not used. READY is an open-drain output to GND with an operating voltage range of GND to VCC. INFET (Pin 20): PowerPath Control Output. For very low dropout applications, this output may be used to drive the gate of an input PMOS pass transistor connected between the DC input (DCIN) and the raw system supply rail (VCC). INFET is internally clamped about 6V below VCC. Maximum operating voltage is VCC. INFET should be left floating if not used. Exposed Pad (Pin 21): This pin provides enhanced thermal properties for the TSSOP. It must be soldered to the PCB copper ground to obtain optimum thermal performance.
U
U
U
4011p
7
LTC4011
BLOCK DIAGRA
1 2 3 4
DCIN FAULT CHRG CHEM THERMISTOR INTERFACE CHARGER STATE CONTROL LOGIC
5 GND VRT VTEMP VCELL
6 7 8
9 10
VCDIV TIMER CHARGE TIMER
8
W
INFET FET DIODE READY VCC 20 19 18 UVLO AND SHUTDOWN TGATE PGND BGATE PWM BAT SENSE BATTERY DETECTOR VOLTAGE REGULATOR INTVDD TOC 14 13 17 16 15 12 11 A/D CONVERTER VOLTAGE REFERENCE INTERNAL VOLTAGE REGULATOR
4011 BD
4011p
LTC4011
OPERATIO U
NO DC ADAPTER SHUTDOWN DC ADAPTER PRESENT NO BATTERY OR VCC < 4.25V CHARGE QUALIFICATION VCELL > 350mV, ADEQUATE VCC, CHARGER ENABLED AND TEMPERATURE OK (OPTIONAL) CHECK BATTERY VCELL > 900mV TOP-OFF CHARGE** (C/10) NiMH T/t VCELL < 900mV PRECHARGE** (C/5 FOR tMAX/12) VCELL < 900mV
VCELL
> 90
0mV
FAST CHARGE** (1C) NiCd OR NiMH - V
VCELL < 1.22V AT tMAX*/12 OR TIME = tMAX
FAULT
tMAX/3
VCELL < 1.325V AUTOMATIC RECHARGE
VCELL > 1.95V OR PWM FAULTS
4011 F01
*tMAX IS PROGRAMMED MAXIMUM FAST CHARGE DURATION **OPTIONAL TEMPERATURE LIMITS APPLY
Figure 1. LTC4011 State Diagram
4011p
9
LTC4011
OPERATIO
Shutdown State
The LTC4011 remains in micropower shutdown until DCIN (Pin 1) is driven above VCC (Pin 8). In shutdown all status and PWM outputs and internally generated terminations or supply voltages are inactive. Current consumption from VCC and BAT is reduced to a very low level. Charge Qualification State Once DCIN is greater than VCC, the LTC4011 exits micropower shutdown, enables its own internal supplies, provides VRT voltage for temperature sensing, and switches VCDIV to GND to allow measurement of the average singlecell voltage. The IC also verifies that VCC is at or above 4.25V, VCC is 500mV above BAT and VCELL is between 350mV and 1.95V. If VCELL is above 1.95V, the fault state is entered, which is described in more detail below. Once adequate voltage conditions exist for charging, READY is asserted. If the voltage between VTEMP and GND is below 200mV, the LTC4011 is paused. If VTEMP is above 200mV but below 2.85V, the LTC4011 verifies that the sensed temperature is between 5C and 45C. If these temperature limits are not met or if its own die temperature is too high, the LTC4011 will indicate a fault and not allow charging to begin. If VTEMP is greater than 2.85V, battery temperature related charge qualification, monitoring and termination are disabled. Once charging is fully qualified, precharge begins (unless the LTC4011 is paused). In that case, the VTEMP pin is monitored for further control. The charge status indicators and PWM outputs remain inactive until charging begins. Charge Monitoring The LTC4011 continues to monitor important voltage and temperature parameters during all charging states. If the DC input is removed, charging stops and the shutdown state is entered. If VCC drops below 4.25V or VCELL drops below 350mV, charging stops and the LTC4011 returns to the charge qualification state. If VCELL exceeds 1.95V, charging stops and the IC enters the fault state. If an external thermistor indicates sensed temperature is beyond a range of 5C to 60C, or the internal die temperature exceeds an
10
U
(Refer to Figure 1)
internal thermal limit, charging is suspended, the charge timer is paused and the LTC4011 indicates a fault condition. Normal charging resumes from the previous state when the sensed temperature returns to a satisfactory range. In addition, other battery faults are detected during specific charging states as described below. Precharge State If the initial voltage on VCELL is below 900mV, the LTC4011 enters the precharge state and enables the PWM current source to trickle charge using one-fifth the programmed charge current. The CHRG status output is active during precharge. The precharge state duration is limited to tMAX/12 minutes, where tMAX is the maximum fast charge period programmed with the TIMER pin. If sufficient VCELL voltage cannot be developed in this length of time, the fault state is entered, otherwise fast charge begins. Fast Charge State If adequate average single-cell voltage exists, the LTC4011 enters the fast charge state and begins charging at the programmed current set by the external current sense resistor connected between the SENSE and BAT pins. The CHRG status output is active during fast charge. If VCELL is initially above 1.325V, cell voltage processing begins immediately. Otherwise -V termination is disabled for a stabilization period of tMAX/12. In that case, the LTC4011 makes another fault check at tMAX/12, requiring the average cell voltage to be above 1.22V. This ensures the battery pack is accepting a fast charge. If VCELL is not above this voltage threshold, the fault state is entered. Fast charge state duration is limited to tMAX and the fault state is entered if this limit is exceeded. Charge Termination Fast charge termination parameters are dependent upon the battery chemistry selected with the CHEM pin. Voltage-based termination (-V) is always active after the initial voltage stabilization period. If an external thermistor network is present, chemistry-specific limits for T/t (rate of temperature rise) are also used in the termination algorithm. Temperature-based termination, if enabled, becomes active as soon as the fast charge state is entered.
4011p
LTC4011
OPERATIO
Top-Off Charge State If NiMH fast charge termination occurs because the T/t limit is exceeded after an initial period of tMAX/12 has expired, the LTC4011 enters the top-off charge state. Top-off charge is implemented by sourcing one-tenth the programmed charge current for tMAX/3 minutes to ensure that 100% charge has been delivered to the battery. The CHRG and TOC status outputs are active during the top-off state. If NiCd cells have been selected with the CHEM pin, the LTC4011 never enters the top-off state. Automatic Recharge State Once charging is complete, the automatic recharge state is entered to address the self-discharge characteristics of nickel chemistry cells. The charge status outputs are inactive during automatic recharge, but VCDIV remains switched to GND to monitor the average cell voltage. If the VCELL voltage drops below 1.325V without falling below 350mV, the charge timer is reset and a new fast charge cycle is initiated. The internal termination algorithms of the LTC4011 are adjusted when a fast charge cycle is initiated from automatic recharge, because the battery should be almost fully charged. Voltage-based termination is enabled immediately and the NiMH T/t limit is fixed at a battery temperature rise of 1C/minute. Fault State As discussed previously, the LTC4011 enters the fault state based on detection of invalid battery voltages during various charging phases. The IC also monitors the regulation of the PWM control loop and will enter the fault state if this is not within acceptable limits. Once in the fault state, the battery must be removed or DC input power must be cycled in order to initiate further charging. In the fault state, the FAULT output is active, the READY output is inactive, charging stops and the charge indicator outputs are inactive. The VCDIV output remains connected to GND to allow detection of battery removal. Note that the LTC4011 also uses the FAULT output to indicate that charging is suspended due to invalid battery or internal die temperatures. However, the IC does not enter the fault state in these cases and normal operation
U
will resume when all temperatures return to acceptable levels. Refer to the Status Outputs section for more detail. Insertion and Removal of Batteries The LTC4011 automatically senses the insertion or removal of a battery by monitoring the VCELL pin voltage. Should this voltage fall below 350mV, the IC considers the battery to be absent. Removing and then inserting a battery causes the LTC4011 to initiate a completely new charge cycle beginning with charge qualification. External Pause Control After charging is initiated, the VTEMP pin may be used to pause operation at any time. When the voltage between VTEMP and GND drops below 200mV, the charge timer pauses, fast charge termination algorithms are inhibited and the PWM outputs are disabled. The status and VCDIV outputs all remain active. Normal function is fully restored from the previous state when pause ends. Status Outputs The LTC4011 open-drain status outputs provide valuable information about the IC's operating state and can be used for a variety of purposes in applications. Table 1 summarizes the state of the four status outputs and the VCDIV pin as a function of LTC4011 operation. The status outputs can directly drive current-limited LEDs terminated to the DC input. The VCDIV column in Table 1is strictly informational. VCDIV should only be used for the VCELL resistor divider, as previously discussed.
Table 1. LTC4011 Status Pins
READY FAULT Off On Off Off CHRG Off Off TOC Off Off VCDIV Off On CHARGER STATE Off Ready to Charge (VTEMP Held Low) or Automatic Recharge Precharge or Fast Charge (May be Paused) NiMH Top-Off Charge (May be Paused) Temperature Limits Exceeded Fault State (Latched) On On On Off Off Off On On On On Off On On On On On On or Off On or Off Off Off
4011p
11
LTC4011
OPERATIO
PWM Current Source Controller An integral part of the LTC4011 is the PWM current source controller. The charger uses a synchronous step-down architecture to produce high efficiency and limited thermal dissipation. The nominal operating frequency of 550kHz allows use of a smaller external filter components. The TGATE and BGATE outputs have internally clamped voltage swings. They source peak currents tailored to smaller surface-mount power FETs likely to appear in applications providing an average charge current of 3A or less. During the various charging states, the LTC4011 uses the PWM controller to regulate an average voltage between SENSE and BAT that ranges from 10mV to 100mV. A conceptual diagram of the LTC4011 PWM control loop is shown in Figure 2. The voltage across the external current programming resistor RSENSE is averaged by integrating error amplifier EA. An internal programming current is also pulled from input resistor R1. The IPROG * R1 product establishes the desired average voltage drop across RSENSE, and hence, the average current through RSENSE. The ITH output of the error amplifier is a scaled control current for the input of
VCC P LTC4011 17 TGATE Q S R PWM CLOCK
N
15 11
BGATE SENSE R3 CC
RSENSE 12 BAT R1
IPROG
Figure 2. LTC4011 PWM Control Loop
12
+
R2
-
U
the PWM comparator CC. The ITH * R3 product sets a peak current threshold for CC such that the desired average current through RSENSE is maintained. The current comparator output does this by switching the state of the SR latch at the appropriate time. At the beginning of each oscillator cycle, the PWM clock sets the SR latch and the external P-channel MOSFET is switched on (N-channel MOSFET switched off) to refresh the current carried by the external inductor. The inductor current and voltage drop across RSENSE begin to rise linearly. During normal operation, the PFET is turned off (NFET on) during the cycle by CC when the voltage difference across RSENSE reaches the peak value set by the output of EA. The inductor current then ramps down linearly until the next rising PWM clock edge. This closes the loop and maintains the desired average charge current in the external inductor. Low Dropout Charging After charging is initiated, the LTC4011 does not require that VCC remain at least 500mV above BAT because situations exist where low dropout charging might occur. In one instance, parasitic series resistance may limit PWM headroom (between VCC and BAT) as 100% charge is reached. A second case can arise when the DC adapter selected by the end user is not capable of delivering the current programmed by RSENSE, causing the output voltage of the adapter to collapse. While in low dropout, the LTC4011 PWM runs near 100% duty cycle with a frequency that may not be constant and can be less than 550kHz. The charge current will drop below the programmed value to avoid generating audible noise, so the actual charge delivered to the battery may depend primarily on the LTC4011 charge timer. Internal Die Temperature The LTC4011 provides internal overtemperature detection to protect against electrical overstress, primarily at the FET driver outputs. If the die temperature rises above this thermal limit, the LTC4011 stops switching and indicates a fault as previously discussed.
R4 ITH EA
4011 F02
4011p
LTC4011
APPLICATIO S I FOR ATIO
External DC Source The external DC power source should be connected to the charging system and the VCC pin through either a power diode or P-channel MOSFET. This prevents catastrophic system damage in the event of an input short to ground or reverse-voltage polarity at the DC input. The LTC4011 automatically senses when this input is present. The opencircuit voltage of the DC source should be between 4.5V and 34V, depending on the number of cells being charged. In order to avoid low dropout operation, ensure 100% capacity at charge termination, and allow reliable detection of battery insertion, removal or overvoltage, the following equation can be used to determine the minimum full-load voltage that should be provided by the external DC power source. DCIN(MIN) = (n * 2V) + 0.3V where n is the number of series cells in the battery pack. The LTC4011 will properly charge over a wide range of DCIN and BAT voltage combinations. Operating the LTC4011 in low dropout or with DCIN much greater than BAT will force the PWM frequency to be much less than 550kHz. The LTC4011 disables charging and sets a fault if a large DCIN to BAT differential would cause generation of audible noise. PowerPath Control Proper PowerPath control is an important consideration when fast charging nickel cells. This control ensures that the system load remains powered at all times, but that normal system operation and associated load transients do not adversely affect fast charge termination. For high efficiency and low dropout applications, the LTC4011 can provide gate drive from the INFET pin directly to an input P-channel MOSFET. The battery should also be connected to the raw system supply by a switch that selects the battery for system power only if an external DC source is not present. Again, for applications requiring higher efficiency, a P-channel MOSFET with its gate driven from the DC input can be used to perform this switching function (see Figure 8). Gate
U
voltage clamping may be necessary on an external PMOS transistor used in this manner at higher input voltages. Alternatively, a diode can be used in place of this FET. Battery Chemistry Selection The desired battery chemistry is selected by programming the CHEM pin to the proper voltage. If it is wired to GND, a set of parameters specific to charging NiMH cells is selected. When CHEM is left floating or connected to VRT, charging is optimized for NiCd cells. The various charging parameters are detailed in Table 2. Programming Charge Current Charge current is programmed using the following equation:
W
UU
RSENSE =
100mV IPROG
RSENSE is an external resistor connected between the SENSE and BAT pins. A 1% resistor with a low temperature coefficient and sufficient power dissipation capability to avoid self-heating effects is recommended. Programming Maximum Charge Times Connecting the appropriate resistor between the TIMER pin and GND programs the maximum duration of various charging states. To some degree, the value should reflect how closely the programmed charge current matches the 1C rate of targeted battery packs. The maximum fast charge period is determined by the following equation:
RTIMER () =
tMAX (Hours) 30 * 10 - 6
Some typical timing values are detailed in Table 3. RTIMER should not be less than 15k. The actual time limits used by the LTC4011 have a resolution of approximately 30 seconds in addition to the tolerances given the Electrical Characteristics table. The maximum time period is approximately 4.3 hours.
4011p
13
LTC4011
APPLICATIO S I FOR ATIO
Table 2. LTC4011 Charging Parameters
STATE PC FC Open GND CHEM PIN BAT CHEMISTRY TIMER Both NiCd NiMH tMAX/12 tMAX tMAX TMIN 5C 5C 5C TMAX 45C 60C 60C ICHRG IPROG/5 IPROG IPROG TERMINATION CONDITION Timer Expires -20mV per Cell or 2C/Minute 1.5C/Minute for First tMAX/12 Minutes if Initial VCELL < 1.325V -10mV per Cell or 1C/Minute After tMAX/12 Minutes or if Initial VCELL > 1.325V TOC AR GND NiMH Both tMAX/3 5C 5C 60C 45C IPROG/10 0 Timer Expires VCELL < 1.325V
PC: Precharge FC: Fast Charge (Initial -V Termination Hold Off of tMAX/12 Minutes May Apply) TOC: Top-Off Charge (Only for NiMH T/t FC Termination After Initial tMAX/12 Period) AR: Automatic Recharge (Temperature Limits Apply to State Termination Only)
Table 3. LTC4011 Time Limit Programming Examples
TYPICAL FAST CHARGE RATE 2C 1.5C 1C 0.75C C/2 PRECHARGE LIMIT (MINUTES) 3.8 5 7.5 10 15 FAST CHARGE VOLTAGE STABILIZATION (MINUTES) 3.8 5 7.5 10 15 FAST CHARGE LIMIT (HOURS) 0.75 1 1.5 2 3 TOP-OFF CHARGE (MINUTES) 15 20 30 40 60
RTIMER 24.9k 33.2k 49.9k 66.5k 100k
Cell Voltage Network Design An external resistor network is required to provide the average single-cell voltage to the VCELL pin of the LTC4011. The proper circuit for multicell packs is shown in Figure 3. The ratio of R2 to R1 should be a factor of (n - 1), where n is the number of series cells in the battery pack. The value of R1 should be between 1k and 100k. This range limits the sensing error caused by VCELL leakage current and prevents the ON resistance of the internal NFET between VCDIV and GND from causing a significant error in the VCELL voltage. The external resistor network is also used to detect battery insertion and removal. The filter formed by C1 and the parallel combination of R1 and R2 is recommended for rejecting PWM switching noise. The value of C1 should be chosen to yield a 1st order lowpass frequency of less than 500Hz. In the case of a single cell, the
BAT 12 LTC4011 VCELL VCDIV 8
14
U
FOR TWO OR MORE SERIES CELLS
W
UU
+
R2
R1 9
C1
R2 = R1(n - 1) GND 5
4011 F03
Figure 3. Mulitple Cell Voltage Divider
external application circuit shown in Figure 4 is recommended to provide the necessary noise filtering and missing battery detection.
4011p
LTC4011
APPLICATIO S I FOR ATIO
12 BAT 10k 10k 1 CELL 9 8 VCDIV VCELL 33nF
4011 F04
Figure 4. Single-Cell Monitor Network
Thermistor Network Design The network for proper temperature sensing using a thermistor with a negative temperature coefficient (NTC) is shown in Figure 5. R3 is only required for thermistors with a room temperature value above 10k. For thermistors with a room temperature value of 10k or less, replace R3 with a short. The LTC4011 is designed to work best with a 1% 10k NTC thermistor with a of 3750. In this case, the values for the external network are given by: R1 = 10.7k R2 = 30.9k R3 = 0 However, the LTC4011 will operate with other NTC thermistors having different nominal values or exponential temperature coefficients. For these thermistors, the general-purpose design equations for the passive resistors in the external linearization network are as follows: where: RO = Thermistor (RT) value at TO () TO = Thermistor reference temperature (K) = Thermistor exponential temperature coefficient of resistance
1.164RO ( - 2TO ) RO ( - 2TO ) 0.141 + 2TO
R1 = R2 = R3 =
11.46 R2 R1RO - (R1 R2 + R1 RO + R2 RO )TO , if RO < 10k (R1+ R2) TO
4011p
U
The filter formed by R4 and C1 in Figure 5 is optional but recommended for rejecting PWM switching noise. Alternatively, R4 may be replaced by a short, and a value chosen for C1 which will provide adequate filtering from the Thevenin impedance of the remaining thermistor network. The filter pole frequency, which should be less than 500Hz, will vary more with battery temperature without R4. External components should be chosen to make the Thevenin impedance from VTEMP to GND 100k or less, including R4, if present.
VRT R1 R4 51k R3 RT R2 VTEMP C1 10nF 6 7
4011 F05
W
UU
Figure 5. External NTC Thermistor Network
Disabling Thermistor Functions Temperature sensing is optional in LTC4011 applications. For low cost systems where temperature sensing may not be required, the VTEMP pin may simply be wired to VRT to disable temperature qualification of all charging operations. However, this practice is not recommended for NiMH cells charged well above or below their 1C rate, because fast charge termination based solely on voltage inflection may not be adequate to protect the battery from a severe overcharge. A resistor between 10k and 20k may be used to connect VTEMP to VRT if the pause function is still desired.
15
LTC4011
APPLICATIO S I FOR ATIO
INTVDD Regulator Output If BGATE is left open, the INTVDD pin of the LTC4011 can be used as an additional source of regulated voltage in the host system any time READY is active. Switching loads on INTVDD may reduce the accuracy of internal analog circuits used to monitor and terminate fast charging. In addition, DC current drawn from the INTVDD pin can greatly increase internal power dissipation at elevated VCC voltages. A minimum ceramic bypass capacitor of 0.1F is recommended. Calculating Average Power Dissipation The user should ensure that the maximum rated IC junction temperature is not exceeded under all operating conditions. The thermal resistance of the LTC4011 package (JA) is 38C/W, provided the exposed metal pad is properly soldered to the PCB. The actual thermal resistance in the application will depend on the amount of PCB copper to which the package is soldered. Feedthrough vias directly below the package that connect to inner copper layers are helpful in lowering thermal resistance. The following formula may be used to estimate the maximum average power dissipation PD (in watts) of the LTC4011 under normal operating conditions.
PD = VCC (7mA + IDD + IVRT + 615k(Q TGATE + Q BGATE)) - 3 IVRT
where: IDD = Average external INTVDD load current, if any IVRT = Load current drawn by the external thermistor network from VRT, if any QTGATE = Gate charge of external P-channel MOSFET in coulombs QBGATE = Gate charge of external N-channel MOSFET (if used) in coulombs VLED = Maximum external LED forward voltage RLED = External LED current-limiting resistor used in the application n = Number of LEDs driven by the LTC4011
V -V - 3.85IDD + 60n CC LED RLED + 30
2
16
U
Sample Applications Figures 6 through 9 detail sample charger applications of various complexities. Combined with the Typical Application on the first page of this data sheet, these Figures demonstrate some of the proper configurations of the LTC4011. MOSFET body diodes are shown in these figures strictly for reference only. Figure 6 shows a minimum application, which might be encountered in low cost NiCd fast charge applications. FET-based PowerPath control allows for maximum input voltage range from the DC adapter. The LTC4011 uses -V to terminate the fast charge state, as no external temperature information is available. Nonsynchronous PWM switching is employed to reduce external component cost. A single LED indicates charging status. A 3A NiMH application of medium complexity is shown in Figure 7. PowerPath control that is completely FETbased allows for both minimum input voltage overhead and minimum switchover loss when operating from the battery. P-channel MOSFET Q4 functions as a switch to connect the battery to the system load whenever the DC input adapter is removed. If the maximum battery voltage is less than the maximum rated VGS of Q4, diode D1 and resistor R5 are not required. Otherwise choose the Zener voltage of D1 to be less than the maximum rated VGS of Q4. R5 provides a bias current of (VBAT - VZENER)/(R5 + 20k) for D1 when the input adapter is removed. Choose R5 to make this current, which is drawn from the battery, just large enough to develop the desired VGS across D1. Precharge, fast charge and top-off states are indicated by external LEDs. The VTEMP thermistor network allows the LTC4011 to accurately terminate fast charge under a variety of applied charge rates. Use of a synchronous PWM topology improves efficiency and lowers power dissipation. A full-featured 2A LTC4011 application is shown in Figure 8. FET-based PowerPath allows for maximum input voltage range from the DC adapter. The inherent voltage ratings of the VCELL, VCDIV, SENSE and BAT pins allow charging of from one to sixteen series nickel cells in this application, governed only by the VCC overhead limits
4011p
W
UU
LTC4011
APPLICATIO S I FOR ATIO
FROM ADAPTER 4.5V TO 34V R 3k INFET FAULT CHRG TOC READY VCC TGATE BGATE 10H
TIMER 49.9k
GND CHEM VCDIV VRT VCELL INTVDD VTEMP 0.1F
Figure 6. Minimum LTC4011 Application
FROM ADAPTER 4.5V TO 34V R
3k R
3k INFET FAULT CHRG TOC READY VCC TGATE
BGATE LTC4011 PGND SENSE
20k
DCIN TIMER 49.9k BAT GND VCDIV CHEM VCELL VRT INTVDD VTEMP 0.1F 10k R2
Figure 7. 3A NiMH Charger with Full PowerPath Control
U
10F TO SYSTEM LOAD PGND LTC4011 SENSE BAT 10k R2 10F 0.1 NiCd PACK (1AHr) 33nF
4011 F06
W
UU
R5 10k TO SYSTEM 20F LOAD
D1 6V
Q4
10H
33m 20F
0.033F
0.068F
30.9k 10.7k
NiMH PACK WITH 10k NTC (3AHr)
4011 F07
4011p
17
LTC4011
APPLICATIO S I FOR ATIO
FROM ADAPTER 4.5V TO 34V
3k G
3k R
3k R
3k Y INFET FAULT CHRG TOC READY VCC TGATE
DCIN TIMER 20k 49.9k
GND VCDIV CHEM VCELL VRT INTVDD VTEMP 0.1F
Figure 8. Full-Featured 2A LTC4011 Application
previously discussed. The application includes all average cell voltage and battery temperature sensing circuitry required for the LTC4011 to utilize its full range of charge qualification, safety monitoring and fast charge termination features. A green LED indicates valid DC input voltage and installed battery, while a pair of red LEDs indicates charging. A yellow LED indicates fault conditions. The grounded CHEM pin selects the NiMH charge termination parameter set. While the LTC4011 is a complete, standalone solution, Figure 9 shows that it can also be interfaced to a host microprocessor. The MCU can control the charger directly with an open-drain I/O port connected to the VTEMP pin, if that port is low leakage and can tolerate at least 2V. The charger state is monitored on the four LTC4011 status outputs. Charging of NiMH batteries is selected in this example. However, NiCd (CHEM VRT) parameters could be chosen as well.
18
U
R5 10k TO SYSTEM LOAD 6V 10F BGATE LTC4011 PGND SENSE 0.05 BAT 10k R2 10F 51k NiCd PACK WITH 10k NTC (2AHr)
4011 F08
W
UU
10H
33nF
22nF
30.9k
10.7k
Unlike all of the other applications discussed so far, the battery continues to power the system during charging. The MCU could be powered directly from the battery or from any type of post regulator operating from the battery. In this configuration, the LTC4011 relies expressly on the ability of the host MCU to know when load transients will be encountered. The MCU should then pause charging (and thus -V processing) during those events to avoid premature fast charge termination. If the MPU cannot reliably perform this function, full PowerPath control should be implemented. Excessive battery load current variations, such as those generated by a post-regulating PWM, can generate sufficient voltage noise to cause the LTC4011 to prematurely terminate a charge cycle and/or prematurely restart a fast charge. In this case, it may be necessary to inhibit the LTC4011 after charging is complete until external gas gauge circuitry indicates that recharging is necessary. Shutdown power is applied to the LTC4011 through the body diode of Q2 in this application.
4011p
LTC4011
APPLICATIO S I FOR ATIO
FROM ADAPTER 4.5V TO 34V V+
STATUS TO MCU
20k TIMER 49.9k GND CHEM VCDIV VCELL 33nF VRT INTVDD VTEMP 0.1F 10.7k PAUSE FROM MCU 68nF 30.9k BAT 10k R2
Figure 9. LTC4011 with MCU Interface
Waveforms Sample waveforms for a standalone application during a typical charge cycle are shown in Figure 10. Note that these waveforms are not to scale and do not represent the complete range of possible activity. The figure is simply intended to allow better conceptual understanding and to highlight the relative behavior of certain signals generated by the LTC4011 during a typical charge cycle. Initially, the LTC4011 is in low power shutdown as the system operates from a heavily discharged battery. A DC adapter is then connected such that VCC rises above 4.25V and is 500mV above BAT. The READY output is asserted when the LTC4011 completes charge qualification. When the LTC4011 determines charging should begin, it starts a precharge cycle because VCELL is less than 900mV. As long as the temperature remains within prescribed limits, the LTC4011 charges (TGATE switching), applying limited current to the battery with the PWM in order to bring the average cell voltage to 900mV.
U
10F Q1 INFET FAULT CHRG TOC READY VCC TGATE Q2 BGATE LTC4011 PGND SENSE 0.1 TO SYSTEM LOAD Q3 10H DCIN NiCd PACK WITH 10k NTC (1AHr)
4011 F09
W
UU
When the precharge state timer expires, the LTC4011 begins fast charge if VCELL is greater than 900mV. The PWM, charge timer and internal termination control are suspended if pause is asserted (VCELL < 200mV), but all status outputs continue to indicate charging is in progress. The fast charge state continues until the selected voltage or temperature termination criteria are met. Figure 10 suggests termination based on T/t, which for NiMH would be an increase of 1C per minute. Because NiMH charging terminated due to T/t and the fast charge cycle had lasted more than tMAX/12 minutes, the LTC4011 begins a top-off charge with a current of IPROG/10. Top-off is an internally timed charge of tMAX/3 minutes with the CHRG and TOC outputs continuously asserted. Finally, the LTC4011 enters the automatic recharge state where the CHRG and TOC outputs are deasserted. The PWM is disabled but VCDIV remains asserted to monitor VCELL. The charge timer will be reset and fast charging will resume if VCELL drops below 1.325V. The LTC4011 enters
4011p
19
LTC4011
APPLICATIO S I FOR ATIO
SHDN PRECHARGE DCIN VCC = 4.25V
READY
VCDIV
TGATE
VCELL VTEMP (PAUSE)
0.9V
CHRG
TOC
Figure 10. Charging Waveforms Example
shutdown when the DC adapter is removed, minimizing current draw from the battery in the absence of an input power source. While not a part of the sample waveforms of Figure 10, temperature qualification is an ongoing part of the charging process, if an external thermistor network is detected by the LTC4011. Should prescribed temperature limits be exceeded during any particular charging state, charging would be suspended until the sensed temperature returned to an acceptable range. Battery-Controlled Charging Because of the programming arrangement of the LTC4011, it may be possible to configure it for battery-controlled charging. In this case, the battery pack is designed to provide customized information to an LTC4011-based charger, allowing a single design to service a wide range of application batteries. Assume the charger is designed to provide a maximum charge current of 800mA (RSENSE = 125m). Figure 11 shows a 5V NiCd battery pack for which
20
U
FAST CHARGE TOP-OFF AUTO RECHARGE SHDN 200mV EXTERNAL PAUSE
4011 F10
W
UU
TIMER 10
CHEM 4 NC
VTEMP 7
+
10k NTC
BATTERY PACK
66.5k
1200mAhr NiCd CELLS
-
4011 F11
Figure 11. NiCd Battery Pack with Time Limit Control
800mA represents a 0.75C rate. When connected to the charger, this pack would provide battery temperature information and correctly configure both fast charge termination parameters and time limits for the internal NiCd cells. A second possibility is to configure an LTC4011-based charger to accept battery packs with varying numbers of cells. By including R2 of the average cell voltage divider network shown in Figure 3, battery-based programming of the number of series-stacked cells could be realized without defeating LTC4011 detection of battery insertion or removal. Figure 12 shows a 2-cell NiMH battery pack
4011p
LTC4011
APPLICATIO S I FOR ATIO
that programs the correct number of series cells when it is connected to the charger, along with indicating chemistry and providing temperature information. Any of these battery pack charge control concepts could be combined in a variety of ways to service custom application needs.
CHEM 4 VTEMP 7 VCELL 8
+
R2
BATTERY PACK
10k NTC
1500mAhr NiMH CELLS
-
4011 F12
Figure 12. NiMH Battery Pack Indicating Number of Cells
PCB Layout Considerations To prevent magnetic and electrical field radiation and high frequency resonant problems, proper layout of the components connected to the LTC4011 is essential. Refer to Figure 13. For maximum efficiency, the switch node rise and fall times should be minimized. The following PCB design priority list will help ensure proper topology. Layout the PCB using this specific order.
SWITCH NODE L1 VBAT HIGH FREQUENCY CIRCULATING PATH
VIN
CIN
D1
COUT
SWITCHING GROUND
Figure 13. High Speed Switching Path
U
1. Input capacitors should be placed as close as possible to switching FET supply and ground connections with the shortest copper traces possible. The switching FETs must be on the same layer of copper as the input capacitors. Vias should not be used to make these connections. 2. Place the LTC4011 close to the switching FET gate terminals, keeping the connecting traces short to produce clean drive signals. This rule also applies to IC supply and ground pins that connect to the switching FET source pins. The IC can be placed on the opposite side of the PCB from the switching FETs. 3. Place the inductor input as close as possible to the drain of the switching FETs. Minimize the surface area of the switch node. Make the trace width the minimum needed to support the programmed charge current. Use no copper fills or pours. Avoid running the connection on multiple copper layers in parallel. Minimize capacitance from the switch node to any other trace or plane. 4. Place the charge current sense resistor immediately adjacent to the inductor output, and orient it such that current sense traces to the LTC4011 are short. These feedback traces need to be run together as a single pair with the smallest spacing possible on any given layer on which they are routed. Locate any filter component on these traces next to the LTC4011, and not at the sense resistor location. 5. Place output capacitors adjacent to the sense resisitor output and ground. 6. Output capacitor ground connections must feed into the same copper that connects to the input capacitor ground before tying back into system ground.
BAT
4011 F13
W
UU
4011p
21
LTC4011
APPLICATIO S I FOR ATIO
7. Connection of switching ground to system ground, or any internal ground plane should be single-point. If the system has an internal system ground plane, a good way to do this is to cluster vias into a single star point to make the connection. 8. Route analog ground as a trace tied back to the LTC4011 GND pin before connecting to any other ground. Avoid using the system ground plane. A useful CAD technique is to make analog ground a separate ground net and use a 0 resistor to connect analog ground to system ground. 9. A good rule of thumb for via count in a given high current path is to use 0.5A per via. Be consistent when applying this rule.
Figure 14. Kelvin Sensing of Charge Current
22
U
10. If possible, place all the parts listed above on the same PCB layer. 11. Copper fills or pours are good for all power connections except as noted above in Rule 3. Copper planes on multiple layers can also be used in parallel. This helps with thermal management and lowers trace inductance, which further improves EMI performance. 12. For best current programming accuracy, provide a Kelvin connection from RSENSE to SENSE and BAT. See Figure 14 for an example. 13. It is important to minimize parasitic capacitance on the TIMER, SENSE and BAT pins. The traces connecting these pins to their respective resistors should be as short as possible.
DIRECTION OF CHARGING CURRENT RSENSE
4011 F14
W
UU
SENSE
BAT
4011p
LTC4011
PACKAGE DESCRIPTIO U
FE Package 20-Lead Plastic TSSOP (4.4mm)
(Reference LTC DWG # 05-08-1663)
Exposed Pad Variation CB
3.86 (.152)
6.40 - 6.60* (.252 - .260) 3.86 (.152) 20 1918 17 16 15 14 13 12 11
6.60 0.10 4.50 0.10
SEE NOTE 4
2.74 (.108) 0.45 0.05 1.05 0.10 0.65 BSC
6.40 2.74 (.252) (.108) BSC
RECOMMENDED SOLDER PAD LAYOUT
1 2 3 4 5 6 7 8 9 10 1.20 (.047) MAX
0 - 8
4.30 - 4.50* (.169 - .177)
0.25 REF
0.09 - 0.20 (.0035 - .0079)
0.50 - 0.75 (.020 - .030)
0.65 (.0256) BSC
NOTE: 1. CONTROLLING DIMENSION: MILLIMETERS MILLIMETERS 2. DIMENSIONS ARE IN (INCHES) 3. DRAWING NOT TO SCALE
0.195 - 0.30 (.0077 - .0118) TYP
0.05 - 0.15 (.002 - .006)
FE20 (CB) TSSOP 0204
4. RECOMMENDED MINIMUM PCB METAL SIZE FOR EXPOSED PAD ATTACHMENT *DIMENSIONS DO NOT INCLUDE MOLD FLASH. MOLD FLASH SHALL NOT EXCEED 0.150mm (.006") PER SIDE
4011p
Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights.
23
LTC4011 RELATED PARTS
PART NUMBER LTC1325 LT(R)1510 LT1511 LT1513 LTC1760 LTC1960 LTC4008 DESCRIPTION Microprocessor-Controlled Battery Management System Constant-Voltage/Constant-Current Battery Charger 3A Constant-Voltage/Constant-Current Battery Charger SEPIC Constant- or Programmable-Current/ConstantVoltage Battery Charger Smart Battery System Manager Dual Battery Charger/Selector with SPI High Efficiency, Programmable Voltage/Current Battery Charger High Efficiency Standalone Nickel Battery Charger Standalone Linear NiMH/NiCd Fast Charger Smart Battery Charger Controller Coulomb Counter/Battery Gas Gauge Low Loss PowerPath Controller COMMENTS Can Charge, Discharge and Gas Gauge Nickel and Lead-Acid Batteries with Software Charging Profiles Up to 1.5A Charge Current for Li-Ion, NiCd and NiMH Batteries High Efficiency, Minimum External Components to Fast Charge Lithium, NiMH and NiCd Batteries Charger Input Voltage May be Higher, Equal to or Lower Than Battery Voltage, 500kHz Switching Frequency Autonomous Power Management and Battery Charging for Two Smart Batteries, SMBus Rev 1.1 Compliant 11-Bit V-DAC, 0.8% Voltage Accuracy, 10-Bit I-DAC, 5% Current Accuracy Constant-Current/Constant-Voltage Switching Regulator, Resistor Voltage/Current Programming, AC Adapter Current Limit and Thermistor Sensor and Indicator Outputs Complete NiMH/NiCd Charger in a Small 16-Pin Package, Constant-Current Switching Regulator Complete NiMH/NiCd Charger in a Small Leaded or Leadless 16-Pin Package, No Sense Resistor or Blocking Diode Required Level 2 Charger Operates with or without MCU Host, SMBus Rev. 1.1 Compliant High Side Sense of Charge Quantity and Polarity in a 10-Pin MSOP Very Low Loss Replacement for Power Supply ORing Diodes Using Minimal External Components
LTC4010 LTC4060 LTC4100 LTC4150 LTC4412
4011p
24
Linear Technology Corporation
1630 McCarthy Blvd., Milpitas, CA 95035-7417
(408)432-1900 FAX: (408) 434-0507 www.linear-tech.com
LT/TP 0205 1K * PRINTED IN THE USA
(c) LINEAR TECHNOLOGY CORPORATION 2005


▲Up To Search▲   

 
Price & Availability of LTC4011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X